MELTMAN Melt Pressure Instrumentation
Edition 01
2026

Product catalogue

Melt pressure
transducers &
transmitters

Strain-gauge melt pressure instrumentation for plastics extrusion, compounding and moulding. Standard, mercury-free, NaK and FDA oil fills. Ranges from 300 to 30,000 psi. Inconel diaphragm as standard, not as an upgrade.

15,000 10,000 5,000 START-UP STEADY STATE SHUT-DOWN
Direct replacement for
DyniscoGefranGentranTerwinISIGP50
Meltman  ·  Focal Point Phase V, Ludhiana, Punjab, India meltmansales@gmail.com  ·  +91 9779722477
MELTMAN Melt Pressure InstrumentationPage 02

How to Specify

Contents
02How to read a part number02
02Choosing a fill02
03Body types — RS, FS, PT, NS, CP03
04Fills & full specification04
05Complete order code05
06Accessories, technical & contact06

How to read a Meltman part number

GGFillStandard
FSBodyFlexible stem
1Length6″ stem + 18″ flex
AOutput3.3 mV/V
PUnitpsi × 1000
5Range0–5,000 psi
6BConnector6-pin bayonet
SIDiaphragmStandard Inconel

Pressure code × unit multiplier = range. P 5 = 5,000 psi · B 3 = 300 bar. Thread and option codes are appended after the diaphragm code, each separated by a hyphen; a blank position means the standard. Fill and body are independent — any of the four fills can be supplied in any of the five body types, with any output.

Choosing a fill

CodeFillMax diaphragm tempMercury freeSpecify when
GGStandard, fluid filled750°F (400°C)NoGeneral extrusion, compounding and moulding
MFMercury free750°F (400°C)YesPlant policy, customer requirement or market regulation excludes mercury
NFNaK1000°F (538°C)YesHigh-temperature engineering polymers; food, medical and pharmaceutical processes
OFDiathermic oil, FDA650°F (350°C)YesLower-temperature processes where FDA approval of the fill is the governing requirement

Fill & ceiling

0 150 300 450 600 MAXIMUM DIAPHRAGM TEMPERATURE °C NF538° GG400° MF400° OF350°
Start with temperature. It removes options absolutely. Then apply the sanitary question — food, medical and pharmaceutical processes exclude mercury regardless of temperature. Whatever survives both is your fill. Then choose the body type from page 03 according to the space you have and whether you need melt temperature from the same hole.
Meltman · Melt pressure productsEdition 01 · 2026
MELTMAN Melt Pressure InstrumentationPage 03

Body Types

Any fill · any output

All five body types are available in every fill — GG, MF, NF and OF — and with every output, from 3.3 mV/V transducers to 4–20 mA and voltage-output transmitters. Drawings are representative and not to scale.

RS
Rigid stem
Transducer / transmitter
6 DIAPHRAGM 6″ STANDARD STEM HOUSING 6-PIN

Housing sits directly at the mounting point. Simplest to install, lowest cost, and correct wherever there is room for it and the electronics are not in a hot spot.

Length   1 3″   2 6″   4 8″   5 9″   6 12″
FS
Rigid stem + flexible capillary
Transducer / transmitter
6 DIAPHRAGM 6″ STEM 18″ ARMOURED FLEX HOUSING

Armoured flexible capillary moves the housing away from the machine. Two reasons to choose it: the electronics sit somewhere cooler, and the connector can be positioned where a cable can actually be routed.

Length   1 6″+18″   2 12″+18″   3 6″+30″   4 12″+30″   5 8″+18″   6 9″+18″   7 3″+18″
PT
Pressure + temperature
Transducer / transmitter
6 T/C J STANDARD — FIELD REPLACEABLE DIAPHRAGM 6″ STEM HOUSING

A temperature sensor mounted directly behind the pressure diaphragm gives both readings from a single mounting hole. It is field replaceable without removing the pressure sensor, which matters because thermocouples fail more often than diaphragms do.

Length as FS  ·  sensor T/C J   TK T/C K   RT Pt100
NS
Narrow space
Transducer / transmitter
6 DIAPHRAGM 0.06″ BARE CAPILLARY ARMOURED FLEX HOUSING

Die faces, adapter blocks and screen changers are crowded, and “there is no room for the sensor” is a common reason a measurement point goes unmonitored. NS removes the rigid stem entirely: a thin bare capillary threads through whatever space exists before meeting the armoured section.

Length   A 28″ flex   B 60″ flex   C 10″ cap + 18″ flex   D 10″ cap + 30″ flex
CP
Compact
Transducer / transmitter
6 DIAPHRAGM 3.5″ STEM SHORT HOUSING Same scale as the bodies above

A shortened body for installations where axial clearance behind the mounting point is the constraint rather than radial space. Same diaphragm, same bridge, same fills.

Length   3 3.5″ stem  ·  from 0–1,000 psi
Meltman · Melt pressure productsEdition 01 · 2026
MELTMAN Melt Pressure InstrumentationPage 04

Fills & Specification

GG · MF · NF · OF

How the sensor works

A melt pressure sensor does not measure pressure where you read it. Process pressure deflects a thin diaphragm at the tip. A sealed, fluid-filled capillary transmits that deflection to a second diaphragm inside the housing, several inches away and much cooler, where a four-active-arm 350 Ω Wheatstone bridge converts it to a millivolt signal proportional to pressure. An internal shunt calibration resistor lets you verify sensor and instrument agree at 80% of full scale without a pressure source. The fluid in that capillary is what the fill code selects, and it governs the temperature the sensor will survive.

GG — standard, fluid filled
  • The industry reference, and the sensor most extrusion lines are already running. Excellent temperature stability across a wide band, which is what keeps the reading honest as a barrel heats up and settles.
  • 750°F (400°C) · 0.5% FS · 15 psi/100°F
MF — mercury free
  • Mechanically and electrically identical to GG, with a mercury-free fill. Same rating, same bodies, same mounting. Specify where mercury is excluded by plant policy, customer requirement, or regulation in the market you ship into.
  • 750°F (400°C) · 0.5% FS · 18 psi/100°F
NF — NaK
  • Sodium-potassium fill raises the ceiling well past what any other fill will tolerate. Two unrelated situations call for it. High temperature — engineering thermoplastics at the top of their windows: PEEK, PEI, PPS, high-temperature polyamides. Sanitary processes — food, medical and pharmaceutical work, where the fill must be regarded as safe in the event of a diaphragm breach.
  • 1000°F (538°C) · 1.0% FS · 10 psi/100°F
OF — diathermic oil, FDA
  • FDA-approved fill for lower-temperature processes where approval of the fill itself is the governing requirement. The temperature ceiling is the constraint — comfortably inside the window for food-contact and medical tubing work, but it will not survive a high-temperature engineering polymer. If the process sits near the limit, specify NF.
  • 650°F (350°C)

Diaphragm selection

CodeMaterialSpecify for
SIStandard InconelGeneral purpose. Fitted as standard, not charged as an upgrade — the tip is where these sensors fail, so that is where the material belongs
ITInconel tip + threadsWhere the thread as well as the tip is exposed to melt
HTHastelloy tip + threadsCorrosive melts — PVC, halogenated and fluoropolymers
TNTitanium nitrideAbrasive melts — glass-filled and mineral-filled compounds
TATitanium aluminium nitrideAbrasive melts at higher temperature
CNChromium nitrideAlternative hard coating for abrasive service
DPDiamond particuliteExtreme abrasion — heavily filled compounds, contaminated regrind
Specifications — common to all bodies and fills unless noted

Mechanical

Ranges
0–300 to 0–30,000 psi
Combined error
0.5% of FS
  NF fill
1.0% of FS
Optional accuracy
0.25% of FS
Repeatability
±0.2%
Overload
2× full scale
Mount torque
150–500 in-lb

Temperature

Max diaph. GG / MF
750°F (400°C)
Max diaph. NF
1000°F (538°C)
Max diaph. OF
650°F (350°C)
Max housing
250°F (120°C)
Zero shift GG
15 psi/100°F
Zero shift MF / NF
18 / 10 psi/100°F
Zero shift, elect.
1%/100°F

Electrical

Sensor
350 Ω bridge
Standard output
3.3 mV/V
Int. shunt cal
80% of FS
Excitation, mV/V
7–12 V (10 V rec.)
Supply, 4–20 mA
14–36 VDC
Supply, 0–10 V
14–36 VDC
Supply, 0–5 V
11–36 VDC
Meltman · Melt pressure productsEdition 01 · 2026
MELTMAN Melt Pressure InstrumentationPage 05

Complete Order Code

All fills · all bodies
One code covers the whole range — fill × body × length × output
Order code XX XX XX X XXXX XXopt
Fill
Body
Length — RS & CP
Length — FS & PT
GG Standard
MF Mercury free
NF NaK
OF Oil, FDA
RS Rigid stem
FS Stem + flex
PT Pressure + temp
NS Narrow space
CP Compact
1 3″   2 6″
4 8″   5 9″
6 12″
3 3.5″ — CP only
1 6″+18″   2 12″+18″
3 6″+30″   4 12″+30″
5 8″+18″   6 9″+18″
7 3″+18″
Length — NS
Output
Pressure unit
Pressure
A 28″ flex
B 60″ flex
C 10″ cap + 18″ flex
D 10″ cap + 30″ flex
A 3.3 mV/V
B 2.5 mV/V
H 2.0 mV/V
C 4–20 mA
D 0–5 VDC
E 1–5 VDC
F 0–10 VDC
G 4–20 mA wire
P psi × 1000
B bar × 100
M MPa
K kg/cm²
0.3   0.5   0.75
1   1.5   3   5
7.5   10   15
20   30
Connector
Diaphragm
Thread
Options — append as needed
6B 6-pin bayonet
6S 6-pin screw
8S 8-pin screw
CS 5-pin China standard
4D 4-pin DIN
.5T 1/2″NPT + 36″ Teflon
SI Standard Inconel
CN Chromium nitride
TN Titanium nitride
TA Ti aluminium nitride
IT Inconel tip + threads
HT Hastelloy tip + threads
DP Diamond particulite
1/2″-20 UNF
18 M18×1.5
14 M14×1.5
10 M10×1.0
T/C J — PT standard
TK Thermocouple K
RT Pt100 RTD
25 0.25% accuracy
EV Epoxy fill
W TIG welded can + epoxy
IP IP65 washdown
VO Voltage output, 3 wire
RL Remote + local zero

Worked examples

Part numberReads as
GGRS2-AP5-6BSIStandard fill, rigid stem 6″, 3.3 mV/V, 0–5,000 psi, 6-pin bayonet, standard Inconel, 1/2″-20 UNF
GGFS1-CP10-6BSIStandard fill, stem + flex 6″+18″, 4–20 mA transmitter, 0–10,000 psi, 6-pin bayonet, standard Inconel
NFPT1-AP10-6BIT-TKNaK fill, pressure + temperature, 6″+18″, 3.3 mV/V, 0–10,000 psi, 6-pin bayonet, Inconel tip and threads, thermocouple K
MFNSC-AP5-6BHT-18Mercury-free fill, narrow space, 10″ capillary + 18″ flex, 3.3 mV/V, 0–5,000 psi, 6-pin bayonet, Hastelloy tip and threads, M18×1.5
OFRS2-AB3-6BSI-25FDA oil fill, rigid stem 6″, 3.3 mV/V, 0–300 bar, 6-pin bayonet, standard Inconel, 0.25% accuracy
Not sure which code you need? Give us the process conditions — melt temperature, working pressure, polymer, the space around the mounting point and what the sensor connects to — and we will build the part number for you. If you are replacing a competitor sensor, the part number on the old unit is usually all we need.
Meltman · Melt pressure productsEdition 01 · 2026
MELTMAN Melt Pressure InstrumentationPage 06

Accessories, Technical Notes & Contact

Reference

Cables & connectors

JacketRatingSpecify when
PVC105°CRouted away from the barrel, no mechanical exposure
PTFE200°CClose to heated zones, oils or solvents present
PTFE + SS braid200°CAbrasion, or where the cable is handled often
PTFE + SS armour200°CCrush risk — trays, walkways, trolley routes

Standard lengths 12, 25 and 50 ft. Cable-end and box-end connectors for every termination we supply. Thermocouple extensions in type J and K.

Mounting & hole preparation

ItemDetail
Hole cut kits1/2″-20 UNF · M18×1.5 · 5/8″-11 · 3/4″-16
Hole clean kitsSame thread sizes
Tip spacers0.025 · 0.032 · 0.045 · 0.063 · 0.090″
Hole plugsSlot · 3″ hex · 6″ hex
Thread adaptorsM18 → 1/2″-20 UNF
Mounting bracketsAll flex-stem builds

Technical notes

Mounting hole
  • A sensor reads what is in front of its diaphragm. Polymer that has degraded and carbonised in the bore ahead of the tip will falsify the reading, and no amount of recalibration will fix it.
  • The diaphragm should finish flush with the bore wall. Proud, and it takes abrasive impact. Recessed, and polymer stagnates in front of it. Tip spacers set the depth exactly.
  • Torque to 150–500 in-lb. Under-tightening leaks; over-tightening distorts the diaphragm and shifts the zero permanently.
  • Fit a hole plug whenever a sensor is out. An open bore fills with degraded polymer.
Zero & shunt calibration
  • Zero drift with temperature is normal and specified. Zero the sensor at operating temperature, not cold.
  • Internal shunt calibration unbalances the bridge by a known amount equal to 80% of full scale, letting you verify that sensor and instrument agree without a pressure source.
  • It checks the electrical path, not the diaphragm. A shunt calibration will pass on a sensor with a coated or blocked tip.
  • Choose a full scale that puts normal running pressure near mid-span, not at the bottom.
Diaphragm selection
  • Abrasion thins the diaphragm until it ruptures. Filled compounds and contaminated regrind do this. Answer with a hard coating — TN, TA or DP.
  • Corrosion attacks the metal chemically and can perforate a diaphragm showing no wear at all. Change the base alloy — HT or IT — because a coating with a pinhole is no protection.
  • Seeing both? Coat a corrosion-resistant base.

Cross-reference

Direct replacement for Dynisco, Gefran, Gentran, Terwin, ISI and GP50. Send us the part number from the sensor you are replacing — or a photograph of the label if it is unreadable — and we will confirm the Meltman equivalent, with no wiring changes and no modification to the mounting bore. If you have no number at all, tell us the machine make and model and we will work backwards.

Warranty & support

WarrantyOne year against manufacturing defects
SupportEvery enquiry is read by someone who understands the products
HoursMonday to Saturday, business hours IST

Contact

AddressFocal Point Phase V, Ludhiana, Punjab, India
Emailmeltmansales@gmail.com
Telephone+91 9779722477
Meltman · Melt pressure productsEdition 01 · 2026